Campbell Manufacturing R410 Modem User Manual


 
Appendix B. Setup Menu
B-2
ii) Radio Standby Modes
(1) Standby Mode
(0 => 24 mA Always ON 3 => 4 mA 1/2 sec Cycle)
(4 => 2 mA 1 sec Cycle 5 => 1 mA 2 sec Cycle)
(6 => .6 mA 4 sec Cycle 7 =>.4 mA 8 sec Cycle)
(2) Time of Inactivity to Sleep
(units of 100 msec; 1 – 32767)
(3) Time of Inactivity to Long Header
(units of 100 msec; 0 – 65535)
Select 0 to always use long header
Select 65535 to never use long header
(4) Long Header Time
(units of 100 msec; 0 – 255)
iii) Radio AT Command Sequence Setup Menu
(1) AT Command Sequence Character
(any ASCII character)
(2) Silence time before Command Sequence
(units of 100 msec; 1 – 32767)
(3) Silence time after Command Sequence
(units of 100 msec; 1 – 32767)
(4) AT Command Mode Timeout
(units of 100 msec; 1 – 32767)
iv) Radio Diagnostics
Number of Retry Failures:
Received Signal Strength:
v) Radio Retry Settings
(1) Number of Retries
(0 – 255)
(2) Number of time slots for random retry
(units of 38 msec; 0 – 255)
(3) Number of bytes transmitted before delay
(1 – 65535)
(4) Sync Timer Setting;
(units of 100 msec; 0 – 255)
b) Interface Parameters
i) CSDC Address (Not Active):
(7 or 8)
ii) RS-232 Auto Power Down Enable
0 => RS-232 always active to power RS-232 devices
1 => RS-232 TX automatically powers down when no activity for 30 sec
iii) RS-232 Parameters
(1) RS-232 Baud Rate:
0 => 1200
1 => 4800
2 => 9600
3 => 19.2k