Field Test Unit Software
print Format,
Pointers
&
buffer
Bypass,
Skip buffer
or Done?
F = Formatted input. (set of B,L,C)
P = Buffer & Pointer format
B = Bypass data unloaded using
“F”
or
“B”
S = " " " " “P”
D = Done (ready to Print)
Log
interval
(min)?
log interval of logger program in minutes
Enter the log period (the time between data recordings) of the logger
program
Bytes per log? number
of bytes logged at each log interval
(max)
Enter the number of bytes recorded each log by the logger
Fields per log?
number of fields from each log that are to
be Plot/Printed. (Separate channels)
Enter the number of fields of the log you wish to print/plot
Enter Scale Size (cm
Horizontal (X axis or time) scale (the
per hour)?
graph is plotted on its side)
Enter the scale of the time axis. This will determine how much paper the
graph will use
Field
[]
Description of each field to be
bytes,from,to,units,
Print/Plotted.
(location,start,end)
bytes = size of field in bytes and optional conversion formula
specifications (or any combination of size plus for-
mula).
RED = Red thermistor correction
from,to
=
are the scales to be used for the range (Y axis up the
graph)
or the scale
printed.
units = (optional) part of the title for the column/field.
location = (optional) byte position in the log entry where the
field begins. If not specified then the
next
byte in
the log entry is assumed to be the start of this field.
(location is counted from
0,
byte 0 being the
lst
byte location in the log entry).
start,end
= (
o
pt
ional) prescale values which set the limits of
valid data for the log entry. If not specified, the data
is assumed to range from 0 to
255
(or 0 to
14
Section 3.
(UN)LOAD,
PLOT& COPY