Cisco Systems ONS 15310-CL Switch User Manual


 
2-77
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
Chapter 2 Alarm Troubleshooting
2.7.113 INC-ISD
2.7.113 INC-ISD
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Object: DS3
The DS-3 Idle condition indicates that the DS-3 port is receiving an idle signal from a 15310-CL-CTX,
ONS 15310-MA DS1-28/DS3-EC1-3, or ONS 15310-MA DS1-84/DS3-EC1-3 DS-1 port, meaning that
the payload of the signal contains a repeating pattern of bits. The INC-ISD condition occurs when the
transmitting port has an OOS-MA,MT service state. It is resolved when the OOS-MA,MT state ends.
Note INC-ISD is a condition and not an alarm. It is for information only and does not require troubleshooting.
2.7.114 INCOMPATIBLE-SEND-PDIP
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
SONET Logical Object: SYSTEM
The Incompatible Software alarm is raised when CTC’S send PDIP provisioning differs from host node's
provisioning.
Clear the INCOMPATIBLE-SEND-PDIP Alarm
Step 1 Reconfigure CTC’s send PDI-P alarm capability to align with the host node settings.
Step 2 If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
for more information or call Cisco TAC (1-800-553-2447).
2.7.115 INCOMPATIBLE-SW
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
SONET SONET Logical Object: NE
The Incompatible Software alarm is raised when CTC cannot connect to the NE due to incompatible
versions of software between CTC and the NE. The alarm is cleared by restarting CTC in order to
redownload the CTC jar files from the NE.
Clear the INCOMPATIBLE-SW Alarm
Step 1 Restart the CTC application.
Step 2 If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
for more information or call Cisco TAC (1-800-553-2447).