Chapter 4 Error Messages
EID-3294 No RMON thresholds available for selected port. Refer to the error message text.
EID-3295 This card does not support RMON thresholds. Refer to the error message text.
EID-3296 Buffer-to-buffer credit is only supported for Fibre Channel (FC)
and FICON.
Refer to the error message text.
EID-3298 ALS Auto Restart is not supported by this interface. Refer to the error message text.
EID-3300 Can not have duplicate OSPF area IDs. OSPF area IDs should be unique.
EID-3301 LAN metric may not be zero. Refer to the error message text.
EID-3302 Standby {0} not ready. Standby controller card is not ready.
EID-3303 DCC Area ID and {0} conflict.
{1}
DCC Area ID and ring type, specified by
{0}, conflict each other due to the details
specified by {1}.
EID-3304 DCC number is out of range. Enter a DCC number that is within the range
EID-3305 Can not have OSPF turned on on the LAN interface and the
back bone area set on a DCC interface.
You cannot have the default OSPF area on a
DCC while OSPF is enabled on the LAN.
EID-3306 Ethernet circuits must be bidirectional. Refer to the error message text.
EID-3307 Error while creating connection object at {0}. CTC encountered an error at the specified
connection while creating the connection.
EID-3308 DWDM Link can be used only for optical channel circuits. Refer to the error message text.
EID-3309 OCH-NC circuit: link excluded - wrong direction. The optical channel (circuit) does not allow
the specified link to be included because it
is in the wrong optical direction.
EID-3310 DWDM Link does not have wavelength available. Refer to the error message text.
EID-3311 Laser already on. Refer to the error message text.
EID-3312 Unable to change the power setpoint {0} {1} CTC cannot change change the power
setpoint. The new setpoint would either
make the thresholds inconsistent or set the
fail threshold outside the range.
EID-3313 Unable to modify offset. Amplifier port is in service state. Refer to the error message text.
EID-3314 Requested action not allowed. Invalid state value. Refer to the error message text.
EID-3315 Unable to perform operation. CTC is unable to perform operation.
EID-3316 Wrong node side. This task was applied to the wrong node
side.
EID-3317 Name too long. Reduce the number of charcters in the
name.
EID-3318 Illegal name. The name you entered is illegal.
EID-3319 Wrong line selection. Select another line
EID-3320 Unable to delete optical link. CTC cannot delete the optical link.
EID-3321 This feature is unsupported by this version of software. Refer to the error message text.
EID-3322 Equipment is not plugged-in. Plug-in the equipment and proceed.
Table 4-1 Error Messages (continued)
Error Warning
ID Error Warning Message Description