Cisco Systems OL-5742-01 Network Router User Manual


 
C-21
Cisco Signaling Gateway Manager User Guide
OL-5742-01
Appendix C SGM Command Reference
sgm cliconntimer
sgm cliconntimer
Solaris Only
Full Syntax
sgm cliconntimer [number-of-seconds | clear]
Command Description
Specifies how long, in seconds, an SGM client is to wait for a message from the
SGM server before exiting. If the timer expires, the client pings the server and
takes the following action:
If the server responds to the ping, the client reconnects to the server.
If the server does not respond to the ping, but there is a backup server
configured, the client connects to the backup server.
If the server does not respond to the ping, and there is no backup server
configured, the client stops.
The valid range is 10 seconds to an unlimited number of seconds. The default
value is 60 seconds.
To restore the default timeout of 60 seconds, enter the sgm cliconntimer clear
command.
Any changes you make take effect when you restart the SGM server.
You must be logged in as the root user or as a super user to use this command.
List of SGM Commands
SGM Command Reference, page C-1.