Citizen CBM1000 Printer User Manual


 
— 145 —
GS C2 n1 n2
[Function] Setting the numbering counter
[Code] <1D>H<43>H<32>H<n1><n2>
[Range] 0
n1 255
0
n2 255
[Outline] This command sets the numbering (serial number counter)
value.
n1 + n2 x 256(n1= remainder, n2=quotient) becomes a counter
value.
[Caution] • If the counter is set with this command, a repeat count of the
idential count will be cleared. If the counter value is beyond
the Range specified with the "GS C1" or "GS C;" command,
the counter will be initialized.
[Default] Not defined.
[See Also] GS C0, GS C1, GS c, GS C;
[Sample Program]
[Print Result] See the sample program and print result for the GS C1
command.