— 54 —
DLE DC4 n m t
[Function] Outputting specified pulse in real-time.
[Code] <10>H<14>H<n><m><t>
[Range] n=1, m=0,1
1
t 8
[Outline] A signal specified with “t” is output to the connector pin
specified with “m”.
m Connector pin
0 Pin No. 2 of drawer Kick-Out Connector
1 Pin No. 5 of drawer Kick-Out Connector
[Details] • On-time and off-time are set at t × 100 msec, respectively.
• In case an error occurred during the processing of this
command, the command is ignored.
• In case (ESC p or DLE DC4 under execution), during the
processing of this command the command is ignored.
• This command will be processed as it is received.
• In specification of serial interface, the command is executed
even in offline, reception buffer full and error conditions.
• In specification of parallel interface, this command cannot be
executed while the printer is BUSY.
• This command will be valid, even if specifying the printer is
invalid due to the selection of peripheral units (ESC =).
[Caution] • If another command with the same data string as this is
received, the printer operates the same way as with this
command. The user should, therefore, be careful.
• The command cannot be inserted in another string of
commands which consist of codes of 2 bytes or more.
[Reference] ESC p