Compaq iP-40 Projector User Manual


 
E-47
Replacement of the Lamp Unit
The projection lamp used on this projector should be replaced after about the number of hours indicated below (or sooner, de-
pending on the usage conditions).
When the usage time exceeds 2000 hours*, the possibility for explosion increases, so the lamp is forcibly shut off.
When the usage time exceeds 1900 hou rs, replace the lamp unit (sold separately) before the usage time reaches 2000 hours.
Also, if the picture is dark, the lamp has reached the end of its service life. Replace it with a new lamp unit.
When the lamp usage time reaches 1900 hours
- Message projected by the projector -
This is displayed when the lamp usage time exceeds 1900 hours.
- Main unit control panel –
The lamp/cover LED ashes red.
The lamp usage time can be checked at the “Installation settings” menu.
When the lamp usage time exceeds 2000 hours
- Message projected by the projector –
The lamp does not light and nothing can be projected.
- Main unit control panel –
The lamp/cover LED lights red.
* The lamp usage time indicated on the menu screen is the time calculated by converting the usage times in the high brightness
and eco modes to the equivalent in the high brightness mode.
Because of this, if you always use the eco mode, the lamp should be replaced after an actual usage time of between 3900 and
4000 hours, but the approximate time the lamp should be replaced is when the lamp usage time indicated on the menu screen
is between 1900 and 2000 hours.
Maintenance
ON/STANDBY
LAMP/COVER
TEMP
INPUT
Do not replace the lamp unit immediately after using the projector.
The lamp is high temperature and you could get burned. Disconnect the power plug from the outlet
and wait one hour or longer before replacing the lamp.
Do not touch the glass portion of the lamp unit with your hands. Doing so could lower the brightness
and shorten the life of the lamp.
There is a large number of glass parts such as the lamp and mirrors that are used inside the pro-
jector. If a glass part breaks, please exercise due caution in handling so that you are not injured by
fragments. Please request repair from the store of purchase or an AVIO customer support center.
WARNING
Please specify the dedicated lamp unit (Model: IPLK-G1).
CAUTION