Compaq Switch 6 Switch User Manual


 
MSA Fabric Switch 6 Management Utility
3-22 Modular SAN Array Fabric Switch 6 User Guide
COMPAQ CONFIDENTIAL
Writer: Kim L. Miller File Name: d-ch3 MSA Fabric Switch 6 Management Utility.doc
Codename: Millebourne Part Number: 230934-002 Last Saved On: 7/17/02 7:52 AM
The Port Control panel displays current information about the port as described in the
following table.
Table 3-6: Port Control Panel
Parameters Description
Status Displays one of the following:
Failed Diagnostics = could not initialize the port; the port has failed.
Loopback mode = loopback cable is attached.
Offline = port was taken offline by management.
No media installed = no SFP installed.
Link down = SFP is installed but with no link established.
Link up = SFP is installed and a link to the device is established.
Link active = SFP is installed, a link to the device is established, and
traffic is flowing.
Isolated = it is understood that the other port is an E-port but complete
initialization cannot be established.
Media Type Displays the media type plugged into the port or that no media interface
is installed.
Detected Port Type Indicates the current port configuration as an F-port, FL-port or E-port,
or other type port.
Set Port Type Allows you to configure the port as one of the following: F-port, FL-port,
E-port, Auto
Port State Displays and allows you to select these values:
On Line = Port is enabled on the Fibre Channel network.
Off Line = Port is disabled from operating on the Fibre Channel network.
continued