Troubleshooting
Modular SAN Array Fabric Switch 6 User Guide 4-5
COMPAQ CONFIDENTIAL
Writer: Kim L. Miller File Name: e-ch4 Troubleshooting.doc
Codename: Millebourne Part Number: 230934-002 Last Saved On: 7/17/02 7:54 AM
Table 4-2: Ethernet Indicators continued
Label Color/Pattern Interpretation Possible Causes
Green/OFF There is no network
link.
If this is off, then there is
no connection to the
network. One or more of
the following could be the
cause:
The network is down for
some reason. Check to
see if other systems on
the network are
functioning.
The switch is not
connected to the network.
Check the cable to see if
it is seated properly. Try
replacing the cable.
The switch is not
functioning. Is the GSI
power showing to the
switch? Can you
communicate with it via
the serial port?
The switch may be
connected to a network
that is not 10Base T
compatible. It could be
100BaseT only, or some
other LAN link.