Datacom Systems VS-1200 Switch User Manual


 
Application 51
© 2009 Datacom Systems Inc
SOLUTION: The VS-1210SFP solves the goals by accepting both sides of each optical network
traffic from four optical tap full-duplex ports and aggregating and replicating the traffic to multiple
ports. The VS-1210SFP also provides media conversion with the small form pluggables so that both
copper and fiber ports are available for connectivity.
CONFIGURATION: The IP address (default 192.168.1.1), Subnet Mask and Default Gateway is set
during the 'Initial Configuration' for your Local Area Network settings and will not be covered in this
section, see the 'IP Address Configuration with TELNET ' section for those steps. Use the syntax
below in the Command Line Interface (CLI) to setup Tap and Any-to-Any ports (syntax is shown
with either user > or Superuser # prompts):
For Configuration, open TELNET on your Management PC and open a hostname connection with
the VS-1210SFP MANAGEMENT RJ45 port. Settings are found in the 'Initial Configuration',
'MANAGEMENT Port Configuration (RJ45)', 'TELNET ' section.
Enter Username (default: Administrator) and Enter key. Enter Password (default: admin) and Enter
key. Default prompt is the > symbol. Enter superuser mode, type su and Enter key. Enter
Password (default: password) and Enter key. Default prompt is the # symbol. Use the following
syntax to set the input/output for Any-to-Any ports as well as the output for Tap ports.
The VS-1200 Series factory default for all Any-to-Any ports is off.
Ensure there are no previous settings present, go through Ports 1-10 and set them to OFF as shown:
# SET PORT MONITOR 1 OFF
# SET PORT MONITOR 2 OFF
# SET PORT MONITOR 3 OFF
# SET PORT MONITOR 4 OFF
# SET PORT MONITOR 5 OFF
# SET PORT MONITOR 6 OFF
# SET PORT MONITOR 7 OFF
# SET PORT MONITOR 8 OFF
# SET PORT MONITOR 9 OFF
# SET PORT MONITOR 10 OFF
32
28