Barcode Fonts
Font Bar Code Length Cksum Valid Characters
A Code 3 of 9 Varies No 0-9, A-Z, -. *$/+% and space char.
B UPC-A 11 digits Yes 0-9
C UPC-E 6 digits Yes 0-9
D Interleaved 2 of 5 Varies No 0-9
E Code 128
(A,B,C)
Varies M-103 entire 128 ASCII character set.
F EAN-13 12 digits Yes 0-9
G EAN-8 7 digits Yes 0-9
H Health Industry
Bar Code
(HIBC)
Varies M-43 0-9, A-Z, -$:/. The Host must
supply leading "+"'s
I Codabar Varies
(Min. 3)
No 0-9, -, ., $, :, /, +, and the start/stop
codes: a, b, c, and d.
J Interleaved 2 of 5
with modulo 10
checksum
Varies M-10 0-9
K Plessey Varies M-10 0-9. Option + is last character for
second M-11 checksum
L Interleaved 2 of 5
with modulo 10
checksum &
shipping bearer
bars
13 M-10 0-9
M UPC 2 digit add. 2 digits Yes 0-9
N UPC 5 digit add. 5 digits Yes 0-9
O Code 93 Varies No All 128 ASCII characters
p Postnet Varies Yes 0-9
Q UCC/EAN Code
128
19 digits Yes 0-9
R UCC/EAN Code
128 K-MART
NON EDI
18 digits Yes 0-9
S UCC/EAN Code
128 Random
Weight
Varies.
At least
34 digits
Yes 0-9
T Telepen Varies Yes All 128 ASCII characters
u UPS MaxiCode 84 Yes 0-9, A-Z
v FIM 1 char. No A, B, C, or D
z PDF-417 Varies Yes All ASCII characters
Table B-3 Valid Bar Code Font ASCII Characters