Dell 840 Personal Computer User Manual


 
Using the System Setup Program 35
Console Redirection Screen
Table 2-5 lists the options and descriptions for the information fields that appear on the
Console
Redirection
screen.
System Security Screen
Table 2-6 lists the options and descriptions for the information fields that appear on the System Security
screen.
Serial Port
(COM1 default)
Serial Port options are COM1, COM3, BMC Serial, BMC NIC, COM1/BMC,
and Off. If an optional remote access controller (RAC) is installed in the system,
RAC is an additional option.
Serial Port shares three usage models. For standard usage, Serial Port attempts to
use COM1 first, and then COM3. For BMC usage, serial port 1 uses the COM1
address and communication can be either via the serial port or the integrated
shared NIC. RAC control uses only the COM1 address.
The COM1/BMC setting allows you to toggle the system between a COM1
setting and BMC Serial setting. In this mode, press <ESC> to enter the BMC
Serial setting and press <ESC><q> to return to the COM1 setting.
Off and COM3 are not available options when Console Redirection is set to use
Serial Port 1.
Speaker
(
On
default)
Enables or disables the system internal speaker.
Table 2-5. Console Redirection Screen Options
Option Description
Console Redirection
(Off default)
Sets the console redirection feature to Serial Port or Off.
Failsafe Baud Rate
(
11520
default)
Displays if the failsafe baud rate is used for console redirection.
Remote Terminal Type
(VT 100/VT 220 default)
Select either VT 100/VT 220 or ANSI.
Redirection After Boot
(Enabled default)
Enables or disables console redirection after your system restarts.
Table 2-4. Integrated Devices Screen Options (continued)
Option Description