34 About Your System
E2017 Timer refresh
failure.
Power cycle
AC.
Timer refresh failure. Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 185.
E2018 Programmable
Timer error.
Power cycle
AC.
Programmable interval
timer error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 185.
E2019 Parity error.
Power cycle
AC.
Parity error. Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 185.
E201A SuperIO
failure.
Power cycle
AC.
SIO failure. Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 185.
E201B Keyboard
controller
error. Power
cycle AC.
Keyboard controller failure. Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 185.
E201C SMI
initialization
failure.
Power cycle
AC.
System management
interrupt (SMI)
initialization failure.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 185.
Code Text Causes Corrective Actions