Dell E05S Server User Manual


 
About Your System 37
W1100 CPU VCORE
Regulator
temp
exceeding
range. Check
fans.
The regulator temperature
reached a point outside the
allowed range.
See "Troubleshooting
System Cooling
Problems" on page 157. If
the problem persists, see
"Getting Help" on
page 185.
W1102 Mem Voltage
Regulator
temp
exceeding
range. Check
fans
The regulator temperature
reached a point outside the
allowed range.
See "Troubleshooting
System Cooling
Problems" on page 157. If
the problem persists, see
"Getting Help" on
page 185.
W1228 RAID
Controller
battery
capacity <
24hr.
Warns predictively that the
RAID battery has less than
24 hours of charge left.
Allow RAID battery to
charge to greater than 24
hours of sustained charge.
If problem persists,
replace the RAID battery.
See "Internal Dual SD
Module (Optional)" on
page 123.
W1630 Power supply
redundancy
degraded.
Check PSU
cables.
The power supply subsystem
is no longer fully redundant.
Reseat the power supplies.
See "Troubleshooting
Power Supplies" on
page 157.
If the problem persists,
see "Getting Help" on
page 185.
NOTE: For the full name of an abbreviation or acronym used in this table, see the
Glossary at support.dell.com/manuals.
Code Text Causes Corrective Actions
book.book Page 37 Wednesday, February 17, 2010 6:17 PM