Dell E06S001 Server User Manual


 
About Your System 29
E141F CPU #
protocol
error. Power
cycle AC.
The system BIOS reported a
processor protocol error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 203.
E1420 CPU Bus
parity error.
Power cycle
AC.
The system BIOS reported a
processor bus parity error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 203.
E1421 CPU #
initializati
on error.
Power cycle
AC.
The system BIOS reported a
processor initialization error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 203.
E1422 CPU # machine
check error.
Power cycle
AC.
The system BIOS reported a
machine check error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 203.
E1610 Power Supply
# (### W)
missing.
Check power
supply.
Specified power supply was
removed or is missing from
the system.
See "Troubleshooting
Power Supplies" on
page 179.
E1614 Power Supply
# (### W)
error. Check
power supply.
Specified power supply
failed.
See "Troubleshooting
Power Supplies" on
page 179.
Code Text Causes Corrective Actions
book.book Page 29 Wednesday, January 20, 2010 10:20 AM