42 About Your System
Alert! iDRAC6 not
responding.
Power required
may exceed PSU
wattage.
Alert!
Continuing
system boot
accepts the risk
that system may
power down
without warning.
The iDRAC6 is hung.
The iDRAC6 was remotely
reset while system was
booting
After AC recovery, the
iDRAC6 takes longer than
normal to boot.
Remove AC power to the
system for 10 seconds and
restart the system.
Alert! Node
Interleaving
disabled! Memory
configuration
does not support
Node
Interleaving.
The memory configuration
does not support node
interleaving, or the
configuration has changed
(for example, a memory
module has failed) so that
node interleaving cannot be
supported. The system will
run but without node
interleaving.
Ensure that the memory
modules are installed in a
configuration that supports
node interleaving. Check
other system messages for
additional information for
possible causes. For memory
configuration information,
see "General Memory
Module Installation
Guidelines" on page 92. If
the problem persists, see
"Troubleshooting System
Memory" on page 181.
Message Causes Corrective Actions