C. Power Supply Specifications
AC POWER SUPPLY (PER POWER SUPPLY)
Wattage
717 Watt (High Output)
570 Watt (Energy Smart)
Voltage
90-264 VAC, autoranging, 47-63Hz
Heat Dissipation
2446.5 BTU/hr maximum (High Output)
1712.9 BTU/hr maximum (Energy Smart)
Maximum Inrush Current
Under typical line conditions and over the entire system ambient
operating range, the inrush current may reach 55A per power supply
for 10ms or less.
D. Environmental Specifications
TEMPERATURE
Operating
10° to 35°C (50° to 95°F) with a maximum temperature gradation of
10°C per hour Note: For altitudes above 2950 feet, the maximum
operating temperature is de-rated 1°F/550 ft
Storage
-40° to 65°C (-40° to 149°F) with a maximum temperature gradation of
20°C per hour
RELATIVE HUMIDITY
Operating
20% to 80% (non-condensing) with a maximum humidity gradation of
10% per hour
Storage
5% to 95% (non-condensing) with a maximum humidity gradation of
10% per hour