Dell R610 Server User Manual


 
Dell™ PowerEdge™ R610 Technical Guidebook
35
Category
Card
Priority
Description Dell PN
PCIe Link
Width
Slot
Priority
Max
Cards
1Gb NIC 10
Intel Gigabit VT Copper
Quad Port NIC
YT674 Gen1 x4 Slot 2, 1 2
1Gb NIC 11
Intel PRO/1000PT Gigabit
Copper Dual Port NIC
X3959 Gen1 x4 Slot 2, 1 2
1Gb NIC 12
Broadcom BCM5709C IPV6
Gigabit Copper Dual Port
NIC with TOE and
iSCSI Ofoad
F169G Gen1 x4 Slot 2, 1 2
1Gb NIC 13
Broadcom BCM5709C IPv6
Gigabit Copper Dual Port
NIC with TOE
G218C Gen1 x4 Slot 2, 1 2
Fibre Channel
8 HBA
14
Emulex LPe12002 FC8 Dual
Channel HBA
C856M Gen2 x4 Slot 1, 2 2
Fibre Channel
8 HBA
15
Emulex LPe12000 FC8 Single
Channel HBA
C855M Gen2 x4 Slot 1, 2 2
Fibre Channel
4 HBA
16
Emulex LPe11002 FC4 Dual
Channel HBA
KN139 Gen1 x4 Slot 1, 2 2
Fibre Channel
4 HBA
17
Emulex LPe1150 FC4 Single
Channel HBA
ND407 Gen1 x4 Slot 1, 2 2
Fibre Channel
4 HBA
18
QLogic QLE2462 FC4 Dual
Channel HBA
DH226 Gen1 x4 Slot 1, 2 2
Fibre Channel
4 HBA
19
QLogic QLE2460 FC4 Single
Channel HBA
PF323 Gen1 x4 Slot 1, 2 2
SCSI HBA 20 LSI Logic LSI2032 SCSI HBA NU947 Gen1 x4 Slot 1, 2 2
Fibre Channel
8 HBA
21
QLogic QLE2562 FC8 Dual
Channel HBA
G444C Gen2 x4 Slot 1, 2 2
Fibre Channel
8 HBA
22
QLogic QLE2560 FC8 Single
Channel HBA
G425C Gen2 x4 Slot 1, 2 2
Fibre Channel
4 HBA
23
QLogic QLE220 FC4 Single
Channel HBA
YY004 Gen1 x4 Slot 1, 2 2
This list was generated based on thermal, mechanical, and performance inputs. Generally speaking,
thermalrequirementswereapriorityforanycardover15W(PERCandmost10GNICcards).Forthe
rest of the cards, thermal requirements were the priority except where there were conflicts with strict
mechanical requirements. Performance considerations were not a factor since both slots were Gen2
with 8x link width.
NOTE:ThePowerEdgeR610supportsamaximumofone25Wcardregardlessofwhichslotispopulated
(does not apply to the Internal Storage Slot). This restriction applies to any PCIe cards that have a
maximumpowerover15W.PCIecardsthatareaectedbythisrestrictionarenotedbyanasterisk.