Dell R610 Server User Manual


 
Dell™ PowerEdge™ R610 Technical Guidebook
16
MAXIMUM VIBRATION
Operating
0.26 Grms at 5 – 350Hz for 5 minutes in operational orientations
Storage
1.54 Grms at 10 – 250Hz for 10 minutes in all orientations
MAXIMUM SHOCK
Operating
Half sine shock in all operational orientations of 31G 5% with a pulse
duration of 2.6 ms 10%
Storage
Half sine shock on all six sides of 71G 5% with a pulse duration of 2 ms
10% Square wave shock on all six sides of 27G with velocity change @
235 in/sec or greater
ALTITUDE
Operating
-16 to 3048 m (-50 to 10,000 ft) Note: For altitudes above 2950 feet, the
maximum operating temperature is de-rated 1°F/550 ft
Storage
-16 to 10,600 m (-50 to 35,000 ft)
E. Power Consumption Testing
FEATURE ENERGY SMART PSU HIGH OUTPUT PSU
Dimensions
L-249 mm
1
x W-65.5 mm x H-38.2 mm
Status Indicators
1 x bi-color Light Emitting Diode
Integrated Fans
None
Fixed Input Plug
IEC-C14
AC Cord Rating
15 Amps @ 120 VAC, 10 Amps @ 240 VAC
Input Voltage
90 – 264 VAC
Auto-ranging
Yes
Line Frequency
47 – 63 Hertz
Maximum Inrush Current
55 Amps per supply for 10 ms or less
Hot-Swap Capability
Yes
Output Power
502 Watts 717 Watts
Maximum Heat Dissipation
1712.9 BTU per hour 2446.5 BTU per hour
Efciency (20% - 100% Load)
86.5 - 90% @ 115 VAC
88 - 92% @ 230 VAC
85 – 88.5% @ 115 VAC
86.5 – 90.5% @ 230 VAC
F. Maximum Input Amps
Maxinputcurrent(HighOutput):10.5A@90VAC,5.3A@180VAC
Maxinputcurrent(EnergySmart):7.0A@90VAC,3.5A@180VAC