Delta Electronics DOP-A Series Network Card User Manual


 
Chapter 3 Element Function|ScrEdit Software User Manual
3-20 Revision Apr. 30th, 2007, 2007PDD23000002
Property Description of Meter Element
Target
Value
Color
The user can decide if the target value display or not by using
this option. If this option is set, the target value and its color set
by the user will display just like the figure shown below: (Here
we set the target value is 60 and its color is in blue.)
Ranges (Enable
range setting)
Please refer to the description of Low & High Region Color.
Variable
target/range limits
When the target value and low & high limit is a variable value,
the low limit address is Read Address+1, the high limit address
is Read Address+2 and the address of target value is Read
Address+3.
Integral Digits
Fractional Digits
Use this option to determine the digit number of integer and
decimal fraction. The digit number is not a real digit number
value. It is only the display format.
When the user has input the target value, minimum and maximum value, after
pressing OK button, HMI will examine the value by referring to the selected data
length, data format, integral and fractional digits.
Low Region Color
High Region Color
This option is available and displayed in the property table only when the “Ranges”
option in the Detail Setup dialog box is selected. If the user sets the low limit value is
30 and the color of low limit region is in green, and then set the high limit value is 70
and the color of high limit region is in red, the meter element will be shown as the
figure below:
Stitch Color It is used to set the stitch color of the meter element.
Scale Color It is used to set the scale color of the meter element.
Scale Region Number
It is used to set the scale region number of the meter element. The user can use the
up or down buttons to increase or decrease the scale region number. The setting
rang is within 1 ~ 10.