Delta Electronics DOP-A Series Network Card User Manual


 
Chapter 2 Creating and Editing Screens|ScrEdit Software User Manual
Revision Apr. 30th, 2007, 2007PDD23000002 2-77
group number (N) into the high byte of this control block and use this control flag to trigger, Dn+5 (Bit 3
is set to ON). After setting, RCPG will be changed to N automatically. This flag needs be set to OFF
and then ON if the user wants to trigger again.
Register for Designating Recipe Number (RBIR)
Word Function
0 Designate receipt number which the user wants to change
By writing recipe group number (N) into Designated Recipe Number Register (RBIR), RCPNO value
can be changed. The user can use the control flag for changing recipe number of Recipe Control
Register (RECR) to write recipe group number (N) into Designated Recipe Number Register (RBIR)
and change RCPNO value.
The following section will introduce how to use recipe. The example is named as recipe.dop and it is
saved in the Example folder under Screen Editor software installation directory.
Please click Tools > Recipe on menu bar and enter into Recipe Setup dialog box. In this example, the
Length is set to 6, Group is set to 7 and Address is set to Internal Memory $220. After complete the
above settings, your Screen will look like the Fig. 2.8.26 shown below.
Fig. 2.8.26 Recipe Setup dialog box