Draytek P2260 Switch User Manual


 
VigorSwitch P2260 User’s Guide
45
In PoE Port Management function, user can configure the settings about PoE.
The switch complies with IEEE 802.3af protocol and be capable of detecting automatically
that whether the device linked to the port on the switch is PD (Powered Device) or not. The
switch also manage the power supplement based on the Class of the PD, and it will stop
supplying the power once the power required by the PD excesses the Class, Short Circuit
or over temperature occurs.
Parameter description:
Status: Include “Normal” or “Active” two kinds of status. The
former means the port is ready to link and supply the power
to the PD at any time. The latter means the port is in the
condition of supplying the power.
State: “Enable” means the manager allows the power supplied to
the PD is legal while the port linked to the PD; “Disable”
means the port does not own PoE function.
Priority: Three options are offered for the user to choose, including
Normal, Low and High. Default is Normal. The switch will
stop supplying the power to the port based on the order of
the priority LowÆNormalÆHigh in case total power
required by all PDs linked to the switch excesses the power
limit. As the ports have the same priority, then the switch
will cease the power supplement from the port with the
highest port id (12Æ1).
Power(W): The power is consumed by the port.
Current(mA): The current is supplied to the PD by the port.
Class: The Class of the PD linked to the port of the switch.