Elmo Tuba Digital Servo Server User Manual


 
A.1.6 Input/Output
Analog Inputs – up to 14-bit resolution
Programmable digital inputs, optically isolated
Inhibit \ Enable motion
Software and analog reference stop
Motion limit switches
Begin on input
Abort motion
General-purpose
Homing
Fast event capture inputs, optically isolated
Programmable digital outputs
Brake Control
Amplifier fault indication
General-purpose
Servo enable indication
Buffered and differential outputs of the main encoder with up to 5 MHz pulses
Buffered and differential outputs of the auxiliary encoder
Emulated output of the resolver, interpolated analog encoder, Tachometer or
Potentiometer
Fast output compare (OC), optically isolated
A.1.7 Built-In Protection
Software error handling
Abort (hard stops and soft stops)
Status reporting
Protection against
Shorts between motor power outputs
Shorts between motor power output and power input/return
Failure of internal power supplies
Overheating
Over/Under voltage
Loss of feedback
Following error
Current limits
Protection against regenerated over-voltage (when using external DC Link)
DC-Linkage extends the limits of the built-in shunt and provides over voltage
protection.
Tuba Installation Guide Technical Specifications
MAN-TUBIG (Ver. 1.3)
A-2