A.5 Power Ratings
Feature Units 12/230 15/230 20/230 12/460 15/460 20/460
Minimum supply voltage VAC 60 140
Nominal supply voltage VAC 1 x 115, 1 x 230, 3 x 230 3 x 400, 3 x 460
Maximum supply voltage VAC 1 x 270 or 3 x 270 3 x 505
Maximum continuous
power output
W 3600 4500 6000 6800 8500 11300
Efficiency at rated power
(at nominal conditions)
% > 93
Auxiliary supply voltage VDC
24 ± 15%
Auxiliary power supply VA
20
Amplitude sinusoidal/DC
continuous current
A 12 15 20 12 15 20
Sinusoidal continuous RMS
current limit (Ic)
A 8.5 10.6 14.1 8.5 10.6 14.1
Peak current limit A 2 x Ic
Built-in shunt (peak power) kW 6 11
Weight
kg
(lbs)
2.7 kg (5.9 lbs)
Dimensions
mm
(in)
247 x 190 x 92 (9.7" x 7.5" x 3.6")
Digital in/Digital
out/Analog in
10/6/2
Mounting method Wall mount (“Bookshelf”) or DIN rail
A.6 Environmental Conditions
Feature Details
Ambient operating temperature 0 °C – 40 °C (32 °F – 104 °F)
Storage temperature -20° ~ +85° C ( -4° ~ +185° F)
Maximum humidity 90% non-condensing
Protection level IP20
Tuba Installation Guide Technical Specifications
MAN-TUBIG (Ver. 1.3)
A-5