EMC 014003051-00 Server User Manual


 
Fibre Channel FC4700 Array to IP4700 File Server Conversion Guide
17
Factory Initialization
11. On the second screen of SPSTAT information, verify the
following:
The system sees all the disk drives and they are unbound.
The system sees all power supplies and fan modules and they
are OK.
NOTE: If you do not see the DAEs and disks you expect, verify that the
Enclosure IDs and cabling are correct. If you need to change them, then you
must reset both SPs. You can reset the SPs by powercycling the system, as
described in step 3 on page 12.
12. At the fcli> prompt, type clearlog and then press <Enter>.
Zero Disk to Clear
Drives
13. At the fcli> prompt, type zd all and then press <Enter>.
The disk LEDs flash randomly on each shelf.
The zero disk function you just implemented enables the fast bind
feature, and takes approximately 15 minutes. Go to step 14 now
while the command executes.
fcli > clearlog
fcli> zd all
Status recvd opcode 0x8a status 0x0