Factory Initialization
14. At the fcli> prompt, t ype spstat and then press <Enter>. Verify
that a ZER has replaced the UNB.
15. At the fcli> prompt, type getlog and then press <Enter>. Verify
that the log reports a Factory Zero Started for each disk
drive.
fcli > spstat
SP A LOOP ID 0x7e (126.)
Microcode Revision: @(#) IP4700 R1.1 p8.4
Press any key to continue....
Statistics Logging: DISABLED PEER SP: PRESENT
Disk Write Caching: DISABLED R3 Write Buffering: DISABLED
WRITE CACHE: DISABLED READ CACHE: DISABLED
RAID OPTIMIZED: Mixed LUNs SP TYPE: IP4700
LUN REMAPPING: DISABLED
A: DP 00TOTAL 0000 DIRTY 0000
B: TOTAL 0000
U: DP 00TOTAL 0000
Requests Complete: 19
SPS A: OK
SPS B: OK
slot: 0 1 2 3 4 5 6 7 8 9 PSA PSB FAN
DPE1-state: ZER ZER ZER ZER ZER ZER ZER ZER ZER ZER OK OK OK OK
Unit/Group : ** ** ** ** ** ** ** ** ** **
DAE1-state: ZER ZER ZER ZER ZER ZER ZER ZER ZER ZER
Unit/Group : ** ** ** ** ** ** ** ** ** **