Emerson MITX-430 Computer Hardware User Manual


 
Operation
MITX-430/MITX-440-DVI-2E Installation and Use Guide (6806800K37B)
88
Bits per second Selects serial port transmission speed. The speed must be matched on
the other side. Long or noisy lines may require lower speeds.
z 9600
z 19200
z 57600
z 115200
Default value is 115200.
Data Bits Data bits of 7 and 8. Default is 8.
Parity Parity bit is sent with the data bits to detect some transmission errors.
Even: parity bit is 0, if the number of 1s in the data bits is even.
Odd: parity bit is 0, if number of 1s in the data bits is odd.
Mark: parity bit is always 1.
Space: Parity bit is always 0.
Mark and Space Parity do not allow for error detection. They can be used
as an additional data bit.
z None
z Even
z Odd
z Mark
z Space
Default value is None.
Stop Bits Stop bits indicate the end of a serial data packet. (Start bit indicates the
beginning). The standard setting is 1 stop bit. Communication with
slow devices may require more than 1 stop bit. The options are 1 and 2.
Default value is 1.
Flow Control Flow control prevents data loss from buffer overflow. While sending
data, if the receiving buffers are full, a stop signal is sent to stop the data
flow. Once the buffers are empty, a start signal is sent to restart the flow.
Hardware flow control uses two wires to send start/stop signals.
Options are None and Hardware RTS/CTS.
Default value is None.
Terminal Resolution Remote Terminal Resolution, 80x25 (default).
Table 5-24 COM1 and COM2 Console Redirection Settings (continued)