Epson 1200 series Scanner User Manual


 
A-4
Technical Specifications
R4C448
Rev. C
A5 size APPA.FM
2/11/00 Pass 3
L
Proof Sign-off:
tanto name SEI Y.Takasaki M.Fujimori
leader name M.Fujimori
editor name SEI M.Kauppi
Electrical
Note:
Check the label on the back of the scanner for voltage information.
Environmental
Temperature:
Operation 5° C to 35° C (41° F to 95° F)
10° C to 32° C (50° F to 89° F)
when using the ADF
Storage –25° C to 60° C (–13° F to 140° F)
Humidity:
Operation 10% to 80%, without condensation
Storage 10% to 85%, without condensation
Operating conditions: Ordinary office or home conditions.
Extreme dust should be avoided.
Operation under direct sunlight or
near a strong light source should be
avoided.
Note:
Specifications are subject to change without notice.
100
120 V model 220
240 V model
Input voltage range AC 90 to 132 V AC 198 to 264 V
Rated frequency 50 to 60 Hz
Rated current 0.5 A 0.3 A
Power consumption Approx. 25W (operating)
Approx. 10W (standby)