Extron electronic IPL T PC1 Power Supply User Manual


 
g Reset button (recessed) — Use the tip of a small Phillips screwdriver or an Extron
Tweeker (provided) to press this recessed button to reset the unit in one of five reset
modes (see “Resetting,” later in this section, for details on reset modes and on using
this Reset button).
h Power LED — This green LED lights while the PC1 or PC1i interface is receiving power
and is running.
When the unit is being reset from the front panel, this LED blinks the appropriate
number of times to indicate the reset mode the PC1 has entered (see “Resetting”).
Setting Up the System Using the Front Panel
The following system setup procedures can be performed using the front panel, Global
Configurator, the embedded web pages, or SIS commands.
This section discusses the front panel procedures. For information on using the web to set
up, see “HTML Configuration and Control.” For the equivalent SIS commands, see “SIS
Programming and Control.” For information on setting up using Global Configurator, see
the IPL T PC1 Setup Guide.
NOTE: The PC1 takes approximately 2 minutes to store settings made via the front
panel, SIS commands, or the web pages into its memory. If you disconnect
power from the PC1 less than 2 minutes after entering a setting, your entry may
be lost.
Setting Up Power Control of the Output Device
To set up power control of the output device plugged into the PC1 output power receptacle:
1. On the PC1 front panel, press and release the receptacle
Receptacle
Power LED
POWER
I
Receptacle
Power Button
Power button.
The green receptacle Power LED at the right of the
button lights and remains lit while the receptacle is
powered on. It turns off when the receptacle is powered
off.
2. Power on the device, using its own power switch.
If power is removed from the PC1, the power state of the output receptacle is preserved
in flash memory; for example, if the receptacle was powered on when the PC1 was
disconnected, it is powered on when the PC1 receives power again. This enables the
receptacle configuration to be easily restored if a power loss occurs.
CAUTION: Some devices, such as projectors, need a cool-down period to power off
safely. Use RS-232 or IR commands to power these devices.
IPL T PC1 • Front Panel Features and Operation 11