Extron electronic IPL T PC1 Power Supply User Manual


 
The response should be the new IP address of the PC1, as shown below.
Figure 11. Ping Command on a Command Prompt Screen
7. After verifying that the IP address change was successful, issue the arp -d command at
the DOS prompt to remove the address from the computer ARP table.
For example:
arp -d 10.13.197.57
A space must separate arp from the hyphen (-).
Setting Up and Configuring the PC1 Using a Web Browser
To set up the PC1 for Ethernet communication using a web browser, you must temporarily
configure the PC to communicate with the interface. Then you can change the default
settings of the PC1 (IP address, subnet mask, and [optionally] administrator name and
password) in order to use the unit on an intranet (LAN) or on the Internet (WAN). After you
have set up the PC1 for network communication, you can reset the computer to its original
network configuration.
IPL T PC1 LAN port defaults
PC1 IP address:
192.168.254.254
Gateway IP address:
0.0.0.0
Subnet mask:
255.255.0.0
DHCP:
Off
Link speed and duplex level:
Auto detected
If you use an existing Ethernet LAN intranet, your network administrator can provide you
with a unique IP address for the PC1 or confirm whether you need to set up the PC1 for
DHCP (Dynamic Host Configuration protocol) to have an address assigned automatically.
IPL T PC1 • HTML Configuration and Control 17