Extron electronic IPL T PC1 Power Supply User Manual


 
X5(
=
IR Playback mode
0 = play once
1 = play continuously
Response is returned with leading zeros.
To stop mode 1 playback, send the IR command again with mode 0 selected.
X6$
=
Time in seconds to keep sending the broadcast message (0-255, default = 10)
X6(
=
(Ethernet only) Number of seconds before timeout on IP connections (min. = 1, max. = 6500, and
default = 30 = 300 seconds).
If no data is received during the timeout period, the Ethernet connection is closed. Each step is 10 seconds. The
response is returned with leading zeros.
X7)
=
The number (as an optional parameter) that is inserted into the e-mail message if the .eml file has an embedded
command (with no parameters).
X7!
=
Hardware (MAC) address: the four most significant hex nibbles converted into a single 16-bit decimal number.
X7@
=
Hardware (MAC) address: the eight least significant hex nibbles converted into a single 32-bit decimal number.
NOTE: This can be up to 10 digits.
X7#
=
E-mail account user name. Maximum length is 31 characters. This parameter is optional; commas cannot be used as
placeholders for it. If it is omitted from an issued command, any existing user account name is cleared.
X7$
=
E-mail account password. Maximum length is 31 characters. This parameter is optional; commas cannot be used as
placeholders for it. If it is omitted from an issued command, any existing user account password is cleared.
X71!
=
Days of the week
1 = Sunday
2 = Monday
3 = Tuesday
4 = Wednesday
5 = Thursday
6 = Friday
7 = Saturday
X71@
=
Time in minutes (0-1440)
0 = 12 am (midnight)
1440 = clear schedule
Example: 1439 = 11:59
Use the following formula (in 24-hour time format): (hour x 60) + minutes = time in minutes
X71#
=
Power receptacle name (12 characters maximum)
IPL T PC1 • SIS Programming and Control 53