Extron electronic ISM 482 Switch User Manual


 
Programmer’s Guide, cont’d
Integration Scaling Matrix Switcher • Programmer’s Guide4-14
Command ASCII Command Response Additional description
(host to switcher) (switcher to host)
Command/response table for IP SIS commands
Command ASCII Command Response Additional description
(host to switcher) (switcher to host)
Delay times
RGB delay (Triple-Action Switching)
X2
*
X20
*3#
X2
Dly
X20
Switching delay of the selected
input to the selected output.
Adjustable in 0.01 second steps
up to 50 = 5.0 seconds. 0 = 0.0
seconds (default), 1 = 0.1
seconds, 2 = 0.2 seconds, and so
on.
Example: 1*35*3# 1Dly35 RGB delay for output 1 set to 3.5
seconds.
Read RGB delay
X2
*3#
X20
Scaler settings
Output sync format
X2
*
X7
*6# Syn
X7
0 = RGBHV (default).
1 = RGBS.
Example: 2*0*6# Syn00 RGBHV signal on output 2.
Read output sync format
X2
*6#
X7
Output polarity
X2
*
X8
*7# Pol
X8
X8
:Horizontal/Vertical polarity
0 = H–/V– 2 = H+/V–
1 = H–/V+ 3 = H+/V+
Example: 1*1*7# Pol01 H–/V+ polarity on output 1.
Read output sync polarity
X2
*7#
X8
Set ISM name (location)
Esc
X30
CN Ipn•
X30
Read ISM name (location)
Esc
CN
X30
Set GMT/date
Esc
X31
CT Ipt•
X32
The date and time entered should be Greenwich Mean Time (GMT).
Read GMT/date
Esc
CT
X32
Set IP address
Esc
X33
CI Ipi•
X33
The switcher sends the response,
but the host may not receive it.
Read IP address
Esc
CI
X33
Read hardware address
Esc
CH
X35
Read # of open connections
Esc
CC
X36
Set administrator password
Esc
X34
CA Ipa
X34
Read administrator password
Esc
CA
X34
Set user password
Esc
X34
CU Ipu
X34
Read user password
Esc
CU
X34
When the computer is connected to the switcher via the RS-232 link, the Admin and User password
fields are not masked. If a password has been inadvertently changed to an unknown value, you can
look up and, if desired, change a password in this window without knowing the current password.
Command/response table for special function SIS commands
The syntax for setting a special function is
X
n
*
X?
# where
X
n
is the value or variable
(such as 35 in the first example below),
X?
is the function number (such as “set RGB
delay” in the first example below), and # is the execute command. To view a
function’s setting, use
X?
# where
X?
is the function number.