3-15Integration Seamless Switcher • Operation
CUT
DISSOLVE
CUT
DISSOLVE
Scaler A
Press Cut or
Dissolve
RS-232 Report
Scaler B
Scaler A
Scaler B
Stay Mode
ISS
Scaler A Changes Inputs Neither Scaler Changes Inputs
Swap Mode
Input 1
(program output)
Input 2
(preview output)
Input 1
(program output)
Input 2
(preview output)
Program Monitor
(input 2)
Preview Monitor
(input 2)
Program Monitor
(input 2)
Preview Monitor
(input 1)
Press Cut or
Dissolve
NO RS-232 Report
ISS
Figure 3-14 — Stay mode and swap mode
Use either the Adjust
knob or the Adjust knob to select Stay or Swap.
PAL Film Mode submenu
The PAL Film Mode submenu lets you turn PAL film mode (2:2 pulldown
detection) on and off for the selected input. The PAL film mode should be used for
a video source that is PAL video that originated from film. PAL film mode applies
video processing algorithms that optimize the conversion of video that was made
with the 2:2 pulldown (PAL video from film) process.
Use either the Adjust
knob or the Adjust knob to select On or Off. Select other
inputs as necessary to configure.
Reset submenu
The Reset submenu resets the ISS 108 or ISS 408 to the default values. Reset the
switcher by pressing and holding the Black/Mute button while this submenu is
active. The LCD displays Unit Reset to Factory Defaults when the reset is