Extron electronic ISS 108 Switch User Manual


 
4-15Integration Seamless Switcher • Programmer’s Guide
Command ASCII Command Response Additional description
(host to switcher) (switcher to host)
Set ISS name (location)
Esc
X30
CN Ipn•
X30
Read ISS name (location)
Esc
CN
X30
Set GMT/date
Esc
X31
CT Ipt•
X32
The date and time entered should be Greenwich Mean Time (GMT).
Read GMT/date
Esc
CT
X32
Set IP address
Esc
X33
CI Ipi•
X33
The switcher sends the response,
but the host may not receive it.
Read IP address
Esc
CI
X33
Read hardware address
Esc
CH
X35
Read # of open connections
Esc
CC
X36
Set administrator password
Esc
X34
CA Ipa•
X34
Read administrator password
Esc
CA
X34
Set user password
Esc
X34
CU Ipu•
X34
Read user password
Esc
CU
X34
When the computer is connected to the switcher via the RS-232 link, the Admin and User password
fields are not masked. If a password has been inadvertently changed to an unknown value, you can
look up and, if desired, change a password in this window without knowing the current password.
Command/response table for IP SIS commands
X30
= ISS name (Up to 240 characters)
X31
= GMT Time and date (set) MM/DD/YY-HH:MM:SS, where
MM = month: 01 (January) through 12 (December)
DD = day: 01 through 31
YY = year: 00 through 99
HH = hour: 00 through 24
MM = minutes: 00 through 59
SS = seconds: 00 through 59
X32
= Time and date (read) In the format: Day,•DD•MMM•YYYY•HH:MM:SS GMT, where
Day = weekday: Mon through Sun
DD = day: 01 through 31
MM = month: Jan through Dec
YYYY = year: 2000 through 2099
HH = hour: 00 through 24
MM = minutes: 00 through 59
SS = seconds: 00 through 59
X33
= IP address ###.###.###.###
X34
= Password 12 digits, alphanumeric
X35
= Hardware address ##-##-##-##-##-##
X36
= Number of open connections 0 - 255