Integration Seamless Switcher • Programmer’s Guide4-8
Automated adjustments
Img
X3
The Auto Image feature has been turned on or off from the front panel for all input
selections.
X3
is the on/off status.
Aut
X3
The auto presets feature has been turned on or off from the front panel for all input
selections.
X3
is the on/off status.
Enh
X3
The enhanced mode feature has been turned on or off from the front panel for
S-video or composite video tied to both outputs.
X3
is the on/off status for the two
outputs.
X2
Reconfig
The input selected for the
X2
output has been adjusted using the Auto Image
feature or a user preset.
Host-to-Switcher Instructions
The switcher accepts SIS commands through its RS-232 port and/or its Ethernet
port. SIS commands consist of one or more characters per command field. They do
not require any special characters to begin or end the command character sequence.
Each switcher response to an SIS command ends with a carriage return and a line
feed (CR/LF = ), which signals the end of the response character string. A string
is one or more characters.
Switcher Error Responses
When the switcher receives an SIS command and determines that it is valid, it
performs the command and sends a response to the host device. If the switcher is
unable to perform the command because the command is invalid or contains
invalid parameters, the switcher returns an error response to the host. The error
response codes are:
E01 — Invalid input channel number (too large)
E10 — Invalid command
E11 — Invalid preset number (too large)
E12 — Invalid output number (too large)
E13 — Invalid value (out of range)
Using the Command/
Response Table
The command/response
table begins on the next page.
Except for the gain and
attenuation settings and the
filter settings, upper or lower
case letters are acceptable in
the command field. The
table at right shows the
hexadecimal equivalent of
each ASCII command.
With the exception of the audio gain and attenuation (G and g) and horizontal
and vertical filtering (D and d) commands, the SIS commands are
not case
sensitive.
ASCII to HEX Conversion Table