Extron electronic MVX PLUS 128 Switch User Manual


 
4-5
MVX Plus 128 VGA Matrix Switchers • Programmer’s Guide
PRELIMINARY
Amtnn*x
]
The switcher initiates the Amt message when an audio output mute is toggled on
or off from the front panel. “nn” is the output number and “x” is the mute status:
1 = on, 0 = off.
Exen
]
The switcher initiates the Exe message when executive mode is toggled on or off
from the front panel. “n” is the executive mode status: 1 = on, 0 = off.
Switcher Error Responses
When the switcher receives an SIS command and determines that it is valid, it
performs the command and sends a response to the host device. If the switcher
is unable to perform the command because the command is invalid or contains
invalid parameters, the switcher returns an error response to the host. The error
response codes are:
E01 — Invalid input channel number (too large)
E10 — Invalid command
E11 — Invalid preset number (too large)
E12 — Invalid output number (too large)
E13 — Invalid value (out of range)
E14 — Illegal command for this confi guration
E17 — Timeout (caused only by direct write of global presets)
E21 — Invalid room number
E24 — Privilege violation (Ethernet, Extron software only)
Using the Command/Response Tables
The command/response tables begin on page 4-7. Lower-case letters are acceptable
in the command fi eld except where indicated for the gain and attenuation
commands. The table below shows the hexadecimal equivalent of each ASCII
character used in the command/response table.
ASCII to HEX Conversion Table
Space
Symbols are used throughout the table to represent variables in the command/
response fi elds. Command and response examples are shown throughout the table.