Communication and Control, cont’d
4-214-20
X38
= Event data size: b = bit; B = byte (8 bit); S = short (16 bit);
L = long (32 bit)
This parameter is case sensitive.
X39
= Event data to write.
X40
=I/O mode: 0 = input; 1 = output; 2 = input plus pull-up resistor;
3 = output plus pull-up resistor; 4 = analog in; 5 = analog in w/
pull-up; 6 = adjust in (requires
X55
&
X56
thresholds); 7 = adjust
in w/pull-up (requires
X55
&
X56
thresholds).
X55
&
X56
thresholds are not required for modes 0-5.
X42
=Setting I/O 0 = off; 1 = on
X43
=0 = off; 1 = on; value = 0-4095, based on 12-bit A to D
X45
=E-mail recipient number: range = 1 - 64 max
X46
=E-mail recipient address: maximum number of characters for a
full email address is 31 characters.
X47
= Name of e-mail file to be sent: the first line of the file is the
subject, the rest is the body of the e-mail.
Email files must have the file extension .eml.
X48
=Event Status fields (8): event_type, event_state, event_paused,
error_status, RcvBuff_endptr, UsrBuff_startptr, UsrBuff_endptr
X49
=Default Name: Combination of model-name and last 3 pairs of
MAC address (e.g., IPL-T-SFI244-00-02-3D)
X50
=Redirect: 0 = no redirect; 1-n = redirect serial port from the
specified port to allow for a transparent pass-through mode
X52
=Connection’s security level: 0 = not logged in; 1 = user;
2 = administrator
X53
=Timeout for data pass-through mode, after which event data can
be inserted into the transmit buffer.
X54
=ASCII digit(s) representing numeric value of data element read
from event buffer (leading zeros are suppressed)
X55
=Upper transition threshold (0 detection = off) for digital inputs;
Lower must be smaller than upper (0-4095 based on 12-bit
A to D)
X56
=Lower transition threshold (1 detection = on) for digital inputs;
Lower must be smaller than upper (0-4095 based on 12-bit
A to D)
The default Web pages will display
X55
and
X56
in
voltages. (100mV to 24VDC, upper default = 2VDC and lower
default = 1VDC). The conversion rate is 162 counts to 1V.
X57
= IR Playback file.
X59
= IR Playback mode: 0 = play once, 1 = play continuously (send
IR command again with mode = 0 to stop mode 1 playback)
X60
= IR Learn starting sample # to return (0 = return all data)
X61
= IR Learn ending sample # to return (0 = return all data)
X62
= IR Learn status: 0 = finished, but no IR seen; 1 = finished, buffer
overrun; 2 = finished, successful collection; 3 = finished, but
aborted; 4 = waiting for first pulse; 5 = busy collecting
X63
= Pulse time in 20MS per count. If parameter is missing or = 0,
pulse length = default (25 counts=500MS), max (65536 counts)
X64
= Broadcast repetition rate in seconds (0-256. 0 = disable)
Copyright information
© COPYRIGHT 2003, EXTRON ELECTRONICS IPL T Mxx,
Vx.xx
Thurs, 20 Feb 2003 17:51:04
The copyright message is displayed upon connecting to IP
Link product via TCP/IP or Telnet. Mxx is the model and
Vx.xx is the firmware version number. The current date and
time are displayed. This is followed by a password prompt.
Password information
The “
Password:” prompt requires a password
(administrator level or user level) followed by a carriage
return. The prompt is repeated if the correct password is not
entered.
If the correct password is entered, the unit responds with
Login Administrator ” or “
Login User
”, depending
on password entered. If passwords are the same for both
administrator and user, the unit will default to administrator
privileges.