4-5SW AV Series Switchers • Remote Control
Command/Response Table for SIS Commands (Continued)
Command ASCII Command Response Additional description
(host to switcher) (switcher to host)
Audio mute
Mute audio 1Z Amt1 Output no audio signal.
Unmute audio 0Z Amt0
Output selected audio input.
Read audio mute Z
X4
Mute status =
X4
.
Audio gain and attenuation
Set gain
X2
*
X6
GIn
X2
•Aud
X5
Set gain for input
X2
to
X6
dB.
Example: 4*3G In004•Aud+03
Set gain for input 4 to 3 dB.
Set attenuation
X2
*
X7
gIn
X2
•Aud
X5
Set attenuation for input
X2
to
X7
dB.
Increment level (specified input)
X2
+G In
X2
•Aud
X5
Increase input
X2
audio level by
+1 dB.
Decrement level (specified input)
X2
-G In
X2
•Aud
X5
Decrease input
X2
audio level by
–1 dB.
View audio level (specified input) V
X2
G
X5
View gain for input
X2
.
Example: V4G In004•Aud=–03 Attenuation for input 4 is set to
–3 dB.
Set gain (current input)
X6
GIn
X2
•Aud
X6
Set gain for the current input to
X6
dB.
Set attenuation (current input)
X7
gIn
X2
•Aud
X7
Set attenuation for the current
input
X7
dB.
Increment level (current input) +G In
X2
•Aud
X5
Increase input
X2
audio level by
+1 dB.
Decrement level (current input) -G In
X2
•Aud
X5
Decrease input
X2
audio level by
–1 dB.
View audio level (current input) G
X5
View gain for input
X2
.
Example: G –03 Attenuation for input 4 is set to
–3 dB.
Front panel security lockout (executive mode)
Lock front panel 1X Exe1 Output no video signal.
Unlock front panel 0X Exe0 Output selected video input.
Read lock status X
X4
Lock status =
X4
Front panel mode
Set normal switch mode 1# F1 Set switch mode to normal.
Set auto switch mode 2# F2 Set switch mode to auto.
Resets
Reset all audio levels to 0 dB
Esc
ZA Zpa
System reset
Esc
ZXXX Zpx Reset to factory defaults
View, information, part number, and firmware requests
Information request IV*
X1
•A*
X1
•F*
X8
Vmt
X4
•Amt
X4
Example: I V*004•A*004•F*1Vmt0•Amt0
Video input 4; audio input 4;
manual switch mode; video mute
off; audio mute off.
Request for part number N nn-nnn-nn
Example: N 60-484-22 60-484-22 = SW 4SVA.
Query software version Q
X9
Example: Q 1.23 Sample value only.