5.3 Replacing Consumables
ScanSnap! fi-4110EOX2 Operator's Guide 59
TROUBLESHOOTING
5
4. When attaching the new Pad ASSY, press down on the pick arm with one hand, and
attach the Pad ASSY with your other hand.
5. Push in the center of the ADF to return it to its original position.
⇒ You should hear the ADF click when it returns to its original position.
ATTENTION
Make sure that the Pad ASSY is completely attached. If the PAD ASSY is not
completely attached, document jams or other feed errors may occur.
Pad ASSY
Push in center.