Fujitsu M8000/M9000 Server User Manual


 
6 SPARC Enterprise M8000/M9000 Servers Product Notes for XCP Version 1060 November 2007
Hardware Installation and Service Issues
This section describes hardware specific issues and workarounds.
Specific Issues and Workarounds
TABLE 1 lists known hardware issues and possible workarounds.
TABLE 1 Hardware Issues and Workarounds
CR ID Description Workaround
6433420 The domain console might display a Mailbox
timeout or IOCB interrupt timeout error during
boot.
Issue a reset -all command from the
OpenBoot PROM (OK) prompt and reboot.
6488846 During boot, the domain console might display
a checksum error for the SG(X)PCI2SCSIU320-
Z SCSI controller I/O card.
Check for the availability of the latest
controller card firmware.
6557379 Power cables are not redundant on single
power feed servers without the dual power
feed option.
On servers that have single power feed, all
power cables must be connected and powered
on at all times.