Fujitsu M8000/M9000 Server User Manual


 
SPARC Enterprise M8000/M9000 Servers Product Notes 29
19. Confirm that both the current and reserve banks of XSCFU#1 display the updated
XCP versions.
If the Current and Reserve banks on XSCF#1 do not indicate XCP revision 1060,
contact your authorized service representative.
Note – Setup RCI network if RCI is used. To setup RCI network, please consult your
service provider.
20. Confirm switching over between XSCFs works properly.
a. When the READY LED on XSCFU_B#1 and the ACTIVE LED on XSCFU_B#0
remain lit, log in to XSCFU#0 using a serial connection or LAN connection.
XSCF> version -c xcp
XSCF#1 (Active)
XCP0 (Reserve): 1060
XCP1 (Current): 1060
XSCF#0 (Standby)
XCP0 (Reserve): 1060
XCP1 (Current): 1060
XSCF> switchscf -t Standby
The XSCF unit switch between the Active and Standby states.
Continue? [y|n] :y