6. Collect an XSCF snapshot to archive system status prior to upgrade.
7. The BUI on XSCFU#0 can be used to upload the XCP 1060 upgrade image.
8. Update the firmware by using the flashupdate(8) command.
Caution – flashupdate(8) will update one bank, reset the XSCF and commence
update of the second bank. Verify that the current and reserve banks are both
updated. If both banks indicate XCP revision 1060, proceed to the next step.
Specify the XCP version to be updated. In this examples, it's 1060.
9. Confirm completion of the update.
Confirm no abnormality happens while updating XCSF_B#0.
10. Confirm that both the current and reserve banks of XSCFU#0 display the updated
XCP versions.
If the Current and Reserve banks on XSCF#0 do not indicate XCP revision 1060,
contact your authorized service representative.
11. Turn off all of the server's mainline switches for 30 seconds.
12. After 30 seconds, turn the mainline switches back on.
XSCF> snapshot -t user@host:directory
XSCF> flashupdate -c update -m xcp -s version
XSCF> showlogs event
XSCF> version -c xcp
XSCF#0 (Active)
XCP0 (Reserve): 1060
XCP1 (Current): 1060
XSCF#1 (Standby)
XCP0 (Reserve): 0000
XCP1 (Current): 0000