28 SPARC Enterprise M8000/M9000 Servers Product Notes for XCP Version 1060 • November 2007
13. Wait until XSCF firmware reaches the ready state.
This can be confirmed when the READY LEDs of XSCF_B#0 and XSCF_B#1 remain
lit.
14. Log in on to XSCFU#0 using a serial connection or LAN connection.
15. Confirm no abnormality occurred by using showlogs error -v and
showstatus(8) commands.
If you encounter any hardware abnormality of the XSCF contact your authorized
service representative.
16. Confirm and update the imported XCP image again.
Specify the XCP version to be updated. In this example, it is 1060. XSCF#1 will be
updated, and then XSCF#0 updated, again.
When the firmware update for XSCF#0 is complete, XSCF#1 is active.
17. Log in to XSCFU#1 using a serial connection or LAN connection.
18. Confirm completion of the update by using the showlogs event command.
Confirm no abnormality is found during the update.
XSCF> showlogs error -v
XSCF> showstatus
XSCF> flashupdate -c update -m xcp -s version
XSCF> showlogs event