6564934 Performing a DR deleteboard(8) operation
on a board which includes Permanent Memory
when using the following network cards
results in broken connections:
X4447A-Z, PCI-e Quad-port Gigabit
Ethernet Adapter UTP
X1027A-Z1, PCI-e Dual 10 Gigabit Ethernet
Fiber XFP Low profile Adapter
Re-configure the affected network interfaces
after the completion of the DR operation. For
basic network configuration procedures, refer
to the ifconfig man page for more
information.
Check for the patch 127741-01 for this detect.
6568417 After a successful CPU DR deleteboard(8)
operation, the system panics when the
following network interfaces are in use:
X4447A-Z, PCI-e Quad-port Gigabit
Ethernet Adapter UTP
X1027A-Z1, PCI-e Dual 10 Gigabit Ethernet
Fiber XFP Low profile Adapter
Add the following line to /etc/system and
reboot the system:
set ip:ip_soft_rings_cnt=0
Check for the patch 127111-02 for this detect.
6571370 Use of the following cards have been observed
to cause data corruption in stress test under
laboratory conditions:
X4447A-Z, PCI-e Quad-port Gigabit
Ethernet Adapter UTP
X1027A-Z1, PCI-e Dual 10 Gigabit Ethernet
Fiber XFP Low profile Adapter
Add the following line in /etc/system and
reboot the system: set
nxge:nxge_rx_threshold_hi=0
For Solaris 10 8/07, check for the patch 127741-
01 for this defect.
For Solaris 10 11/06, check for the patch
125670-04 for this defect.
6572827 On SPARC Enterprise M8000/M9000 servers,
one of the columns in the IO Devices section of
the output from prtdiag -v is "Type". This
reports "PCIe", "PCIx", "PCI" or "UNKN" for
each device.
The algorithm used to compute this value is
incorrect. It reports "PCI" for PCI-X leaf
devices and "UNKN" for legacy PCI devices.
There is no workaround.
6584984 On SPARC Enterprise M8000/M9000 servers,
busstat(1M) command may cause rebooting
of domains.
None available at this time. Do not use
busstat(1M) command.
Check for the availability of a patch for this
defect.
6588650 On occasion, the system is unable to DR after
an XSCF failover or XSCF reboot.
There is no workaround. Check for the
availability of a patch for this defect.
TABLE 4 Specific Issues and Workarounds Concerning Solaris (Continued)
CR ID Description Workaround