Fujitsu RX330 Server User Manual


 
RX330 S1 Operating manual 39
Hardware installation Installing/removing the server in/from the rac
k
4.2.1 Installation in PRIMECENTER/DataCenter Rack
For installation in a PRIMECENTER/DataCenter Rack, the following parts are
required:
Support bracket
One left and one right telescopic rail (assembled)
M5x10 screws with integrated plugwashers
I Or, M5x10 screws with separate plugwashers can also be used. In
this case, two plugwashers each must be fitted beforehand on the
support uprights and the support bracket.
The descriptions and figures in this section refer to the current
variable support.
General information is provided in the Technical Manual for the
PRIMECENTER and/or DataCenter Rack (see “Literature” on
page 87).
When mounting the left telescopic rail in the PRIMECENTER/DataCenter Rack,
the supplied support bracket must first be mounted on the rear left support
upright flush with the bottom edge of the device.
Figure 3: Fitting the support bracket
Ê Position the support bracket at the corresponding height on the rear left
support upright, (insert lug in corresponding hole) (1).
Ê Secure the bracket with two screws incl. plug washers (2).
2