RX330 S1 Operating manual 57
Starting up and operation Switching the server on and off
Switching the server OFF
Power-on indicator (position 10 in figure 11 on page 49) lights green.
Ê Shut down the operating system properly.
The server is automatically switched off. The Power-on indicator lights red.
I If the operating system does not switch the server off automatically,
press the On/Off button for at least four seconds and/or send a corre-
sponding control signal.
Other on/off options
In addition to the On/Off button, the server can be switched ON and OFF in the
following ways:
Specified switch on time / switch off time
The server is switched ON or OFF at a time specified in the ServerView
program
Ring indicator
The server is switched on by an internal or external modem.
Wake On LAN (WOL)
The server is switched on by a command via the LAN (Magic Packet).
After power failure
The server automatically reboots following a power failure (depending of the
settings in the BIOS).
“Power override” function
The server can be switched off immediately by pressing and holding the
On/Off button (approx. 4-5 sec.).
V CAUTION!
There is a risk that data may be lost.