Fujitsu RX330 Server User Manual


 
RX330 S1 Operating manual 43
Hardware installation Installing/removing the server in/from the rac
k
Racks with installation depth smaller/greater than 735 mm
The lengths of the telescopic rails have to be adjusted with respect to each other
when installing in rack systems with an installation depth greater than/less than
735 mm. The length is adjusted with the spring element on the variable support
Ê Secure the telescopic rails as described in section “Installation in PRIME-
CENTER/DataCenter Rack” on page 39.
Ê Mount the server (see section “Inserting the server” on page 43) and route
the cables as described in the rack manual.
4.2.3 Inserting the server
Figure 6: Preparing the server
Ê Place the server rails on the three screws on both sides of the server (1) and
slide the server rails forwards to secure them (2).
The safety spring (a) must engage with an audible click.
1
2
a