XG2600 Hardware Guide Chapter 2 Installation
Installation of the switch
30
Caution
• Do not install PSUs to face the front side of the rack. They do not work properly.
• Before installing the switch in the rack, check if the airflow direction of the fans is correct. If the
air flows incorrectly, it may cause failure to the switch
The diagram below shows in which slots PSUs need to be installed and airflow direction of the fans.
: Installing – : not installing
The LED lights in a correct configuration as follows:
– : Unsupported because the unit is not installed
If the LED indicators are different from the above, it may be due to the incorrect configuration of PSUs and/or Fans, or
there may be failures with PSUs and/or Fans.
Power Supply Unit Fan Unit
Switch Interface Side Switch Fan Unit Side FAN1 Slot FAN2 Slot
PSU1 Slot PSU2 Slot PSU1 Slot PSU2 Slot Installation Airflow Installation Airflow
––
Intake
Intake
Switch Interface Side
Power Supply Unit Switch Fan Unit Side
Switch Interface
Side
Switch
Fan Unit Side
Slot 1/Slot 2
READY CHECK PSU1 PSU2 FAN
PSU1 PSU2 PSU1 PSU2
STATUS OUTFLOW
POWER
Green Off Green Green Green Green Green – – Green Off