Magnum 6K32 & 6K32T Managed Switch Installation and User Guide (12/05)
30
www GarrettCom com
..
4. By default it is NC (normally closed)
5. The software operation needs to be enabled and set to get the Alarm traps. For detailed
information about the Software Alarm and software control of SNMP alarm traps, please
reference the Magnum MNS-6K Software User Manual. (Chapter 19th).
3.5 6K32T Port Module (6KPM) Installation
The Magnum 6K32T Switches are normally received from the factory with 24
ports fixed and one required 6KPM module installed. There may be situations where
6KPM cards need to be added or replaced. In cases where a 6KPM module needs to be
added in the modular slot, the faceplate for an available front-mounted slot must be
removed. The following procedure describes this operation.
3.5.1 Preparation for Installing and Removing 6KPMs
STOP!!!
Be sure the power cord and connections
for all powers single or dual, is unplugged
from the chassis before attempting to remove
and/or replace any PM cards.
Failure to do so may result in damage to the unit
and will void the warranty.
Caution- Avoid Static Discharge: The port modules (like most electronic
equipment) are sensitive to static discharge. Use proper ESD measures
when handling port modules.
Step 1. Make sure the 6KPM Card package has all necessary accessories to install it
properly. Each 6KPM Card package for field installation contains
(Daughterboard (Bigger) and Granddaughter board (smaller), three 5/8 stand
offs for the Granddaughter board, six #4-40 Pan-Head screws along with a
Front panel face plate package. The Front panel faceplate package includes 3
retainer brackets and six #2-56 flat head screws.
NOTE: Every 6KPM Card package comes with their matching Daughter and
Granddaughter board. The copper 6KPM card should not work properly if
mixed with other Fiber combo 6KPM card packages. Always install the PM
module separately one by one to avoid the mixing.